COOLANT DISTRIBUTION UNIT

In-Row Liquid-to-Liquid CDU

DeepCoolAI in-row liquid-to-liquid CDUs provide the thermal and hydraulic interface between facility and technology cooling loops for high-density and direct-to-chip liquid-cooled data centers.

One CDU. Multiple Cooling Architectures.

Support diverse server configurations, varying coolant flow requirements, and evolving AI deployments with a flexible liquid cooling platform built for today's high-density data centers.

001-data science.png

Multiple Redundancy Options

Reduce downtime by configuring pump architecture to meet your desired level of redundancy, serviceability, and cooling performance.

025-thermometer.png

High-Efficiency Heat Exchange

Optimized heat exchanger design delivers reliable, high-capacity thermal management for demanding AI workloads.

036-setting.png

Six Capacity Variants

Choose from 600kW to 2.5MW to support everything from enterprise deployments to hyperscale AI data centers.

  • Designed to Grow with Your Infrastructure

    • Modular cabinet architecture

    • Parallel installation support

    • Configurable 1-, 2-, or 3-pump configurations

    • Supports multiple cooling system sizes

  • Precision Flow & Pressure Management

    • Flow rate control modes

    • Pressure differential control

    • Real-time monitoring

    • Integrated sensors throughout the cooling loop

  • Built for Faster Serviceability

    • Automatic fill pump

    • Automatic air vents

    • Front and rear service access

    • Flange or clamp piping connections

  • Flexible for Mixed Cooling Environments

    • Compatible with multiple coolant types

    • Supports different server flow requirements

    • Designed for a variety of liquid cooling architectures

  • Intelligent Monitoring & Connectivity

    • HMI touchscreen

    • Modbus RTU/IP

    • SNMP

    • BACnet

    • HTTP

    • SMTP

    • Comprehensive pressure, flow, temperature, and water quality monitoring

  • Built for AI Deployments
    Wetted materials are selected in accordance with the latest NVIDIA-approved materials guidance for liquid-cooled AI infrastructure.

DSC01316.png

A CDU Built For The Future

Whatever your infrastructural requirements, our L2L CDUs support and scale to fit your needs, reliably and efficiently.

professionals-troubleshooting-in-a-data-center-ser-2026-01-09-11-06-47-utc.jpg

Reduce Commissioning Time

Automatic fill pumps, integrated air vents, and simplified piping connections accelerate startup and reduce manual intervention.

Screenshot 2026-07-13 152444.png

Maximize Uptime

Redundant pumps and dual power feeds provide continuous cooling for mission-critical AI infrastructure.

Fans.png

Optimize Thermal Performance

Electronic pumps automatically adjust to changing cooling loads.

Data-Center.png

Scale with Confidence

Modular architecture and parallel installation support allow cooling capacity to grow alongside your data center.

Server-room.png

Simplify Operations

Comprehensive monitoring, open communication protocols, and integrated sensors provide complete visibility into CDU performance and water quality.

*Specifications may vary based on model and capacity

  • DCAI-IWL-600-B

    Rated Cooling Capacity:

    • 600 kW @ 5 C ATD

    Envelope:

    • 800 W x 2000 D x 2000 H mm

  • DCAI-IWL-1400

    Rated Cooling Capacity:

    • 1,400 kW approx. @ 4 C ATD

    Envelope:

    • 900 W x 1200 D x 2200 H mm

  • DCAI-IWL-1600-FW

    Rated Cooling Capacity:

    • 1,600 kW @ 4.5 C ATD

    Envelope:

    • 900 W x 1285.8 D x 2113.5 H mm

  • DCAI-IWL-1800-B

    Rated Cooling Capacity:

    • 1,600 kW @ 4.5 C ATD

    Envelope:

    • 1200 W x 2000 D x 2100 H mm

  • DCAI-IWL-2000-OCP-B

    Rated Cooling Capacity:

    • 2,000 kW @ 3 C ATD

    Envelope:

    • 1651 W x 1061 D x 2242 H mm

  • DCAI-IWL-2500-BM

    Rated Cooling Capacity:

    • 2,500 kW @ 4.5 C ATD

    Envelope:

    • 1200 W x 2000 D x 2300 H mm

  • Modular capability is available, allowing multiple connected units to provide total capacities of 5 MW, 7.5 MW, 10 MW, and higher as required.

    ​

    Get in touch for more details