COOLANT DISTRIBUTION UNIT
In-Row Liquid-to-Liquid CDU
DeepCoolAI in-row liquid-to-liquid CDUs provide the thermal and hydraulic interface between facility and technology cooling loops for high-density and direct-to-chip liquid-cooled data centers.
One CDU. Multiple Cooling Architectures.
Support diverse server configurations, varying coolant flow requirements, and evolving AI deployments with a flexible liquid cooling platform built for today's high-density data centers.

Multiple Redundancy Options
Reduce downtime by configuring pump architecture to meet your desired level of redundancy, serviceability, and cooling performance.

High-Efficiency Heat Exchange
Optimized heat exchanger design delivers reliable, high-capacity thermal management for demanding AI workloads.

Six Capacity Variants
Choose from 600kW to 2.5MW to support everything from enterprise deployments to hyperscale AI data centers.
Designed to Grow with Your Infrastructure
-
Modular cabinet architecture
-
Parallel installation support
-
Configurable 1-, 2-, or 3-pump configurations
-
Supports multiple cooling system sizes
-
Precision Flow & Pressure Management
-
Flow rate control modes
-
Pressure differential control
-
Real-time monitoring
-
Integrated sensors throughout the cooling loop
-
Built for Faster Serviceability
-
Automatic fill pump
-
Automatic air vents
-
Front and rear service access
-
Flange or clamp piping connections
-
Flexible for Mixed Cooling Environments
-
Compatible with multiple coolant types
-
Supports different server flow requirements
-
Designed for a variety of liquid cooling architectures
-
Intelligent Monitoring & Connectivity
-
HMI touchscreen
-
Modbus RTU/IP
-
SNMP
-
BACnet
-
HTTP
-
SMTP
-
Comprehensive pressure, flow, temperature, and water quality monitoring
-
Built for AI Deployments
Wetted materials are selected in accordance with the latest NVIDIA-approved materials guidance for liquid-cooled AI infrastructure.

A CDU Built For The Future
Whatever your infrastructural requirements, our L2L CDUs support and scale to fit your needs, reliably and efficiently.

Reduce Commissioning Time
Automatic fill pumps, integrated air vents, and simplified piping connections accelerate startup and reduce manual intervention.

Maximize Uptime
Redundant pumps and dual power feeds provide continuous cooling for mission-critical AI infrastructure.

Optimize Thermal Performance
Electronic pumps automatically adjust to changing cooling loads.

Scale with Confidence
Modular architecture and parallel installation support allow cooling capacity to grow alongside your data center.

Simplify Operations
Comprehensive monitoring, open communication protocols, and integrated sensors provide complete visibility into CDU performance and water quality.
*Specifications may vary based on model and capacity
DCAI-IWL-600-B
Rated Cooling Capacity:
-
600 kW @ 5 C ATD
Envelope:
-
800 W x 2000 D x 2000 H mm
-
DCAI-IWL-1400
Rated Cooling Capacity:
-
1,400 kW approx. @ 4 C ATD
Envelope:
-
900 W x 1200 D x 2200 H mm
-
DCAI-IWL-1600-FW
Rated Cooling Capacity:
-
1,600 kW @ 4.5 C ATD
Envelope:
-
900 W x 1285.8 D x 2113.5 H mm
-
DCAI-IWL-1800-B
Rated Cooling Capacity:
-
1,600 kW @ 4.5 C ATD
Envelope:
-
1200 W x 2000 D x 2100 H mm
-
DCAI-IWL-2000-OCP-B
Rated Cooling Capacity:
-
2,000 kW @ 3 C ATD
Envelope:
-
1651 W x 1061 D x 2242 H mm
-
DCAI-IWL-2500-BM
Rated Cooling Capacity:
-
2,500 kW @ 4.5 C ATD
Envelope:
-
1200 W x 2000 D x 2300 H mm
-
Modular capability is available, allowing multiple connected units to provide total capacities of 5 MW, 7.5 MW, 10 MW, and higher as required.