COOLANT DISTRIBUTION UNIT

In-Row Liquid-to-Liquid CDU

A liquid-to-liquid Coolant Distribution Unit (CDU) in a data center is a specialized system crafted to oversee the distribution of liquid coolant within a closed-loop liquid cooling infrastructure. Unlike liquid-to-air CDUs, which utilize heat exchangers to transfer heat from IT equipment to the air, liquid-to-liquid CDUs facilitate direct heat transfer between liquid coolant circuits.


DeepCoolAI offers in-row L2L CDUs up to 2.5MW capacity.

In-Row Liquid-to-Liquid CDU
In-Row Liquid-to-Liquid CDU

Rated Cooling Capacity

Coolant Flow Rate

Power Supply

Dimensions H x W x D

1600kW @ ADT=5°C

Dry Weight

341 GPM

AC480V/3Ph/60Hz (other voltage options available)

2200 x 900 x 1200mm (87" x 35" x 47")

950kg (2095 lb)

Get Your

Custom Quote

Product
DSC01316.png

DeepCoolAI in-row liquid-to-liquid CDUs provide the thermal and hydraulic interface between facility and technology cooling loops for high-density and direct-to-chip liquid-cooled data centers.

One CDU. Multiple Cooling Architectures.

Support diverse server configurations, varying coolant flow requirements, and evolving AI deployments with a flexible liquid cooling platform built for today's high-density data centers.

001-data science.png

Multiple Redundancy Options

Reduce downtime by configuring pump architecture to meet your desired level of redundancy, serviceability, and cooling performance.

025-thermometer.png

High-Efficiency Heat Exchange

Optimized heat exchanger design delivers reliable, high-capacity thermal management for demanding AI workloads.

036-setting.png

Six Capacity Variants

Choose from 600kW to 2.5MW to support everything from enterprise deployments to hyperscale AI data centers.

  • Designed to Grow with Your Infrastructure

    • Modular cabinet architecture

    • Parallel installation support

    • Configurable 1-, 2-, or 3-pump configurations

    • Supports multiple cooling system sizes

  • Precision Flow & Pressure Management

    • Flow rate control modes

    • Pressure differential control

    • Real-time monitoring

    • Integrated sensors throughout the cooling loop

  • Built for Faster Serviceability

    • Automatic fill pump

    • Automatic air vents

    • Front and rear service access

    • Flange or clamp piping connections

  • Flexible for Mixed Cooling Environments

    • Compatible with multiple coolant types

    • Supports different server flow requirements

    • Designed for a variety of liquid cooling architectures

  • Intelligent Monitoring & Connectivity

    • HMI touchscreen

    • Modbus RTU/IP

    • SNMP

    • BACnet

    • HTTP

    • SMTP

    • Comprehensive pressure, flow, temperature, and water quality monitoring

  • Built for AI Deployments
    Wetted materials are selected in accordance with the latest NVIDIA-approved materials guidance for liquid-cooled AI infrastructure.

A CDU Built For The Future

Whatever your infrastructural requirements, our L2L CDUs support and scale to fit your needs, reliably and efficiently.

professionals-troubleshooting-in-a-data-center-ser-2026-01-09-11-06-47-utc.jpg

Reduce Commissioning Time

Automatic fill pumps, integrated air vents, and simplified piping connections accelerate startup and reduce manual intervention.

Screenshot 2026-07-13 152444.png

Maximize Uptime

Redundant pumps and dual power feeds provide continuous cooling for mission-critical AI infrastructure.

Fans.png

Optimize Thermal Performance

Electronic pumps automatically adjust to changing cooling loads.

Data-Center.png

Scale with Confidence

Modular architecture and parallel installation support allow cooling capacity to grow alongside your data center.

Server-room.png

Simplify Operations

Comprehensive monitoring, open communication protocols, and integrated sensors provide complete visibility into CDU performance and water quality.

*Specifications may vary based on model and capacity

  • DCAI-IWL-600-B

    Rated Cooling Capacity:

    • 600 kW @ 5 C ATD

    Envelope:

    • 800 W x 2000 D x 2000 H mm

  • DCAI-IWL-1400

    Rated Cooling Capacity:

    • 1,400 kW approx. @ 4 C ATD

    Envelope:

    • 900 W x 1200 D x 2200 H mm

  • DCAI-IWL-1600-FW

    Rated Cooling Capacity:

    • 1,600 kW @ 4.5 C ATD

    Envelope:

    • 900 W x 1285.8 D x 2113.5 H mm

  • DCAI-IWL-1800-B

    Rated Cooling Capacity:

    • 1,600 kW @ 4.5 C ATD

    Envelope:

    • 1200 W x 2000 D x 2100 H mm

  • DCAI-IWL-2000-OCP-B

    Rated Cooling Capacity:

    • 2,000 kW @ 3 C ATD

    Envelope:

    • 1651 W x 1061 D x 2242 H mm

  • DCAI-IWL-2500-BM

    Rated Cooling Capacity:

    • 2,500 kW @ 4.5 C ATD

    Envelope:

    • 1200 W x 2000 D x 2300 H mm

  • Modular capability is available, allowing multiple connected units to provide total capacities of 5 MW, 7.5 MW, 10 MW, and higher as required.

    Get in touch for more details

Modular_Design_DeepCool.png

Ready To Future Proof Your Operation?

There's no time like the present, get in touch today

Key Features:

 

  • High efficiency energy saving: Aannually free cooling ultra-low energy consumption

  • High reliability: Key components redundancy, condensation protection, circulation pump, valve keeps function. Dual power input, switch over without shutdown, leakage detection

  • Smart control: Multi-mode, pressure diff. control, flow rate control, cold standby, hot standby, independent operation, group control, local/remote control, group control

  • High compatibility: CPU plus GPU cold plate liquid cooling combined application

  • High availability: Wide range cooling capacity, pressure drop adjustable, step-less control

  • High flexibility: multi optional function available, top or bottom coolant connections, filter class, communication, etc.

  • Modular design: Combined cabinet installation

  • Easy maintenance: Rreasonable internal layout, frontal and rear access, automatic online refilling

  • High cleanness: Hhygiene pipe with fine filtration

  • Communication: RS485, RJ45

  • Protocol: Modbus, TCP, UDP